安装150加仑日节水升级会两倍数量的产品水生产相同数量的浪费水。这意味着你只需要运行您的RO / DI单元的一半长,因此您将使用一半的废水)没有装备。它通过利用这一过程被称为废水暂存。废水暂存是一种流行的技术在许多工业反渗透应用程序。它允许您添加第二个膜串联再加工废水从第一个膜。因为第二废水的膜被美联储第一膜,它将处理更高的TDS水然后第一。与相当干净的水这不会有任何真正的明显影响,但如果你有一个传入的TDS 300 TDS或更高,这将产生更明显的影响,你可能会更快地消耗DI树脂。出于这个原因,我们一般不建议使用TDS自来水高的装备。安装150加仑日节水升级工具:1。安装新的膜成膜的住房和螺钉帽2。 Snap the membrane clips to the new membrane housing. 3. Snap the new membrane housing to the existing membrane housing. 4. Remove the waste water line from the existing membrane housing. 5. Route a tube from the waste water line from the existing membrane to the feed port of the new membrane. 6. Install the waste water line that was on the existing membrane housing onto the waste water port of the new housing. 7. Remove the product water line that connects the existing membrane housing to the auto shut off valve. 8. Cut two new product water lines and connect the product water lines together by running a line from each product water output to the included tube divider (Y fitting). 9. Connect the combined output of the tube divider to the product water input of the auto shut off valve. That is it, you are done! Connect with us on Facebook: http://www.facebook.com/BulkReefSupply Check out our pics on Instagram: http://instagram.com/bulkreefsupply